The close monitoring of blood pressure during a caesarean section performed under central neuraxial anaesthesia should be the standard of safe anaesthesia. As classical oscillometric and invasive blood pressure measuring have intrinsic disadvantages, we investigated a novel, non-invasive technique for continuous blood pressure measuring. Methods: In this monocentric, retrospective data analysis, the reliability of continuous non-invasive blood pressure measuring using ClearSight® (Edwards Lifesciences Corporation) is validated in 31 women undergoing central neuraxial anaesthesia for caesarean section. In addition, patients and professionals evaluated ClearSight® through questioning. Results: 139 measurements from 11 patients were included in the final analysis. Employing Bland-Altman analyses, we identified a bias of -10.8 mmHg for systolic, of -0.45 mmHg for diastolic and of +0.68 mmHg for mean arterial blood pressure measurements. Pooling all paired measurements resulted in a Pearson correlation coefficient of 0.7 for systolic, of 0.67 for diastolic and of 0.75 for mean arterial blood pressure. Compensating the interindividual differences in linear regressions of the paired measurements provided improved correlation coefficients of 0.73 for systolic, of 0.9 for diastolic and of 0.89 for mean arterial blood pressure measurements. Discussion: Diastolic and mean arterial blood pressure are within an acceptable range of deviation from the reference method, according to the Association for the Advancement of Medical Instrumentation (AAMI) in the patient collective under study. Both patients and professionals prefer ClearSight® to oscillometric blood pressure measurement in regard of comfort and handling.
Titel | The Use of Non-Invasive Continuous Blood Pressure Measuring (ClearSight®) during Central Neuraxial Anaesthesia for Caesarean Section-A Retrospective Validation Study. |
---|---|
Medien | Journal of Clinical Medicine |
Verlag | --- |
Heft | --- |
Band | 2022/11/15 |
ISBN | 2077-0383 |
Verfasser/Herausgeber | Philipp Helmer, Daniel Helf, Prof. Dr. Michael Sammeth, Bernd Winkler, Sebastian Hottenrott, Patrick Meybohm, Peter Kranke |
Seiten | --- |
Veröffentlichungsdatum | 2022-08-02 |
Projekttitel | --- |
Zitation | Helmer, Philipp; Helf, Daniel; Sammeth, Michael; Winkler, Bernd; Hottenrott, Sebastian; Meybohm, Patrick; Kranke, Peter (2022): The Use of Non-Invasive Continuous Blood Pressure Measuring (ClearSight®) during Central Neuraxial Anaesthesia for Caesarean Section-A Retrospective Validation Study.. Journal of Clinical Medicine 2022/11/15, e42359. DOI: 10.3390/jcm11154498 |