Helmer, Philipp; Rodemers, Philipp; Hottenrott, Sebastian; Leppich, Robert; Helwich, Maja; Pryss, Rüdiger; Kranke, Peter; Meybohm, Patrick; Winkler, Bernd E; Sammeth, Michael (2023)
Helmer, Philipp; Rodemers, Philipp; Hottenrott, Sebastian; Leppich, Robert...
iScience 2023/26/11, 108155.
DOI: 10.1016/j.isci.2023.108155
Blood oxygen saturation is an important clinical parameter, especially in postoperative hospitalized patients, monitored in clinical practice by arterial blood gas (ABG) and/or pulse oximetry that both are not suitable for a long-term continuous monitoring of patients during the entire hospital stay, or beyond. Technological advances developed recently for consumer-grade fitness trackers could-at least in theory-help to fill in this gap, but benchmarks on the applicability and accuracy of these technologies in hospitalized patients are currently lacking. We therefore conducted at the postanaesthesia care unit under controlled settings a prospective clinical trial with 201 patients, comparing in total >1,000 oxygen blood saturation measurements by fitness trackers of three brands with the ABG gold standard and with pulse oximetry. Our results suggest that, despite of an overall still tolerable measuring accuracy, comparatively high dropout rates severely limit the possibilities of employing fitness trackers, particularly during the immediate postoperative period of hospitalized patients.
Sammeth, Michael; Ursache, Nicu-Cosmin; Alboaie, Sînică (2023)
Frontiers in Blockchain 2023/6, 1126978.
DOI: 10.3389/fbloc.2023.1126978
Introduction: Distributed ledger networks, chiefly those based on blockchain technologies, currently are heralding a next-generation of computer systems that aims to suit modern users’ demands. Over the recent years, several technologies for blockchains, off-chaining strategies, as well as decentralised and respectively self-sovereign identity systems have shot up so fast that standardisation of the protocols is lagging behind, severely hampering the interoperability of different approaches. Moreover, most of the currently available solutions for distributed ledgers focus on either home users or enterprise use case scenarios, failing to provide integrative solutions addressing the needs of both.
Methods: Herein, we introduce the OpenDSU platform that allows to interoperate generic blockchain technologies, organised–and possibly cascaded in a hierarchical fashion–in domains. To achieve this flexibility, we seamlessly integrated a set of well conceived components that orchestrate off-chain data and provide granularly resolved and cryptographically secure access levels, intrinsically nested with sovereign identities across the different domains. The source code and extensive documentation of all OpenDSU components described herein are publicly available under the MIT open-source licence at https://opendsu.com.
Results: Employing our platform to PharmaLedger, an inter-European network for the standardisation of data handling in the pharmaceutical industry and in healthcare, we demonstrate that OpenDSU can cope with generic demands of heterogeneous use cases in both, performance and handling substantially different business policies.
Discussion: Importantly, whereas available solutions commonly require a pre-defined and fixed set of components, no such vendor lock-in restrictions on the blockchain technology or identity system exist in OpenDSU, making systems built on it flexibly adaptable to new standards evolving in the future.
Helmer, Philipp; Hottenrott, Sebastian; Rodemers, Philipp; Leppich, Robert; Helwich, Maja; Pryss, Rüdiger; Kranke, Peter; Meybohm, Patrick; Winkler, Bernd E; Sammeth, Michael (2022)
Helmer, Philipp; Hottenrott, Sebastian; Rodemers, Philipp; Leppich, Robert...
Journal of Medical Internet Research 24(12), e42359.
DOI: 10.2196/42359
Background: Over the recent years, technological advances of wrist-worn fitness trackers heralded a new era in the continuous monitoring of vital signs. So far, these devices have primarily been used for sports.
Objective: However, for using these technologies in health care, further validations of the measurement accuracy in hospitalized patients are essential but lacking to date.
Methods: We conducted a prospective validation study with 201 patients after moderate to major surgery in a controlled setting to benchmark the accuracy of heart rate measurements in 4 consumer-grade fitness trackers (Apple Watch 7, Garmin Fenix 6 Pro, Withings ScanWatch, and Fitbit Sense) against the clinical gold standard (electrocardiography).
Results: All devices exhibited high correlation (r≥0.95; P<.001) and concordance (rc≥0.94) coefficients, with a relative error as low as mean absolute percentage error <5% based on 1630 valid measurements. We identified confounders significantly biasing the measurement accuracy, although not at clinically relevant levels (mean absolute error<5 beats per minute).
Conclusions: Consumer-grade fitness trackers appear promising in hospitalized patients for monitoring heart rate.
Helmer, Philipp; Helf, Daniel; Sammeth, Michael; Winkler, Bernd; Hottenrott, Sebastian; Meybohm, Patrick; Kranke, Peter (2022)
Helmer, Philipp; Helf, Daniel; Sammeth, Michael; Winkler, Bernd; Hottenrott, Sebastian...
Journal of Clinical Medicine 2022/11/15, e42359.
DOI: 10.3390/jcm11154498
The close monitoring of blood pressure during a caesarean section performed under central neuraxial anaesthesia should be the standard of safe anaesthesia. As classical oscillometric and invasive blood pressure measuring have intrinsic disadvantages, we investigated a novel, non-invasive technique for continuous blood pressure measuring. Methods: In this monocentric, retrospective data analysis, the reliability of continuous non-invasive blood pressure measuring using ClearSight® (Edwards Lifesciences Corporation) is validated in 31 women undergoing central neuraxial anaesthesia for caesarean section. In addition, patients and professionals evaluated ClearSight® through questioning. Results: 139 measurements from 11 patients were included in the final analysis. Employing Bland-Altman analyses, we identified a bias of -10.8 mmHg for systolic, of -0.45 mmHg for diastolic and of +0.68 mmHg for mean arterial blood pressure measurements. Pooling all paired measurements resulted in a Pearson correlation coefficient of 0.7 for systolic, of 0.67 for diastolic and of 0.75 for mean arterial blood pressure. Compensating the interindividual differences in linear regressions of the paired measurements provided improved correlation coefficients of 0.73 for systolic, of 0.9 for diastolic and of 0.89 for mean arterial blood pressure measurements. Discussion: Diastolic and mean arterial blood pressure are within an acceptable range of deviation from the reference method, according to the Association for the Advancement of Medical Instrumentation (AAMI) in the patient collective under study. Both patients and professionals prefer ClearSight® to oscillometric blood pressure measurement in regard of comfort and handling.
Coelho, Vitor Lima; Fontenele de Brito, Tarcísio; Alexandre de Abreu Brito, Ingrid; Arruda Cardoso, Maira; Berni, Mateus Antonio; Araujo, Helena Maria Marcolla; Sammeth, Michael; Pane, Attilio (2021)
Coelho, Vitor Lima; Fontenele de Brito, Tarcísio; Alexandre de Abreu Brito, Ingrid...
Scientific Reports 2021, 1918 (11).
DOI: 10.1038/s41598-021-81387-1
Rhodnius prolixus is a Triatominae insect species and a primary vector of Chagas disease. The genome of R. prolixus has been recently sequenced and partially assembled, but few transcriptome analyses have been performed to date. In this study, we describe the stage-specific transcriptomes obtained from previtellogenic stages of oogenesis and from mature eggs. By analyzing ~ 228 million paired-end RNA-Seq reads, we significantly improved the current genome annotations for 9206 genes. We provide extended 5' and 3' UTRs, complete Open Reading Frames, and alternative transcript variants. Strikingly, using a combination of genome-guided and de novo transcriptome assembly we found more than two thousand novel genes, thus increasing the number of genes in R. prolixus from 15,738 to 17,864. We used the improved transcriptome to investigate stage-specific gene expression profiles during R. prolixus oogenesis. Our data reveal that 11,127 genes are expressed in the early previtellogenic stage of oogenesis and their transcripts are deposited in the developing egg including key factors regulating germline development, genome integrity, and the maternal-zygotic transition. In addition, GO term analyses show that transcripts encoding components of the steroid hormone receptor pathway, cytoskeleton, and intracellular signaling are abundant in the mature eggs, where they likely control early embryonic development upon fertilization. Our results significantly improve the R. prolixus genome and transcriptome and provide novel insight into oogenesis and early embryogenesis in this medically relevant insect.
Fakultät Angewandte Naturwissenschaften und Gesundheit (FNG)
Friedrich-Streib-Str. 2
96450 Coburg
T 09561317659 Michael.Sammeth[at]hs-coburg.de